FIL Lisbon Venue Sheet: Pavilion Sizes, Heights and Rules

FIL (Feira Internacional de Lisboa) in Parque das Nações has four exhibition pavilions of 10,000 m² each, with a 15 m ceiling in Pavilion 1, 12 m in Pavilions 2 to 4 and a floor load of 2,000 kg/m². FIL’s General Regulation sets a general stand height of up to 3 m: anything taller, and any second floor, needs FIL’s technical approval, with drawings submitted at least 20 days before build-up.

Last updated: 24 Nov 2026

This is a reference sheet, not a sales page. Every figure comes from FIL’s own websites (fil.pt and the venue site fil.lisbonvenues.pt) or from FIL’s General Regulation, and the source is linked next to it. Where FIL publishes no venue-wide figure, we leave the item out instead of estimating. This is our own independent summary, not a FIL publication. FIL’s documents and your event’s participation rules always prevail.

Which documents apply?

The base document is the FIL General Regulation (Regulamento Geral da FIL, PDF, Portuguese), also shown as “Condições Gerais” on FIL’s regulation page. FIL publishes it in Portuguese only; the article numbers below (for example “RG 7.2”) refer to that PDF. Each fair adds its own “Normas de Participação” (participation rules), which take precedence over the General Regulation for that event (RG 1.2). Dates, duration and opening hours are set for each event in a separate FIL document (RG 1.3).

The “Regulamento Específico” on the same FIL page applies to events at the Centro de Congressos de Lisboa (CCL), not to the FIL pavilions, so this sheet does not use it.

FIL at a glance

Item Official figure Source
Address Rua do Bojador, Parque das Nações, 1998-010 Lisboa, Portugal FIL: Location
Exhibition pavilions 4 multifunction pavilions of 10,000 m² gross each FIL: Pavilions
Total complex Over 100,000 m² FIL: Pavilions
Covered exhibition area 60,000 m², which belongs to the 4 pavilions fil.pt: Visitantes
Climate Fully air-conditioned; no smoking inside the buildings fil.pt: regulation page, questions tab
At FIL since 1999, when FIL moved from Junqueira to Parque Expo fil.pt: Sobre a FIL

The four pavilions: reference table

Source for every row: FIL: Pavilions (Portuguese version: Pavilhões). Figures are copied as FIL prints them.

Pavilion Gross area Width Length Ceiling height Floor load
Pavilion 1 10,000 m² 72 m 142 m 15 m 2,000 kg/m²
Pavilion 2 10,000 m² 72 m 142 m 12 m 2,000 kg/m²
Pavilion 3 10,000 m² 72 m 142 m 12 m 2,000 kg/m²
Pavilion 4 10,000 m² 72 m 142 m 12 m 2,000 kg/m²

Note on length: FIL’s text and its “each pavilion” list give 142 m, while the summary table on the same page prints 141 m. We show 142 m and flag the difference so you can confirm it on the general floor plan (PDF) if a few centimetres matter to your layout.

What each pavilion includes

  • A metal grid in the roof structure for mounting suspensions, and “possibility for rigging across entire pavilion” (FIL: Pavilions).
  • Floor with equipped technical gutters (cable ducts).
  • 14 meeting rooms of 10 to 50 m² on the upper level of each pavilion.
  • An installed transformer capacity of 6,250 kVA, air-conditioning, CCTV and fire detection.
  • A catering support room and a gate to the loading dock.

Floor plans: general plan, Pavilion 1, Pavilion 2, Pavilion 3, Pavilion 4.

Other FIL spaces

Space What FIL says Source
Multiuse Pavilion 1,070 m², between Pavilions 2 and 3, wooden structure, direct access from the pedestrian zone FIL: Multiuse Pavilion
Sony Square Approx. 15,000 m² outdoors at the north end; used for open-air events or as an area complementary to large events, joining with Pavilion 4 FIL: Sony Square
Grand Hall Main entrance on the south side, two floors. Floor 0: access to the pavilions, registration, Exhibitor Support Office, ServiFIL, first aid and treasury. Floor 1: press and VIP rooms FIL: Grand Hall
Loading dock Exterior area with 300 spaces and room to manoeuvre; sometimes used as exhibition space for large equipment; entrance at the north end FIL: Entrances

Stand rules from the General Regulation

Source for every row: FIL General Regulation; article numbers in brackets. The English wording is our translation.

Topic Rule Article
Space module 9 m² (3.00 × 3.00 m); a stand takes one module or a multiple of it. Spaces come without platforms, walls or partitions RG 7.1
General stand height Up to 3 m RG 7.2
Taller stands Submitted to FIL’s technical area at least 20 days before build-up starts, with dimensioned plans, elevations and sections RG 7.2
Second floor Needs FIL’s express authorisation. The usable upper floor, and any decorative element above 3 m, must be set back at least 1.50 m from the stand perimeter RG 7.2
Second-floor cost Extra participation cost of 50% of the built usable area, at the unit price of the space RG 4.2
Raised floors Any stand with a raised floor needs a ramp for wheelchair users RG 7.2
Carpet Only fire-retardant carpet, fire class M3 RG 7.3
On-site work No workshop construction anywhere in the exhibition area; no cutting machines, welding, sanders or spray painting. Stands must be built only by assembling prepared elements RG 7.4
Venue equipment Fire hydrants, extinguishers, loudspeakers, signage, CCTV and fire detectors must be respected RG 7.2
Exhibit loads Special authorisation for products over 2,000 kg/m² on the pavilion floor, or over 200 kg/m² on a stand’s first floor RG 5.4
Hanging from the building Only with FIL’s authorisation and only by FIL’s concessionaires, at FIL’s price list. Request at least 20 days before the event, with the suspension project and the weights RG 7.16
Walls and structure No hanging or fixing of exhibits, decoration or construction elements on pavilion walls or structural elements without FIL’s express authorisation RG 7.17

Electricity and services

Topic Rule Article
Supply 230/400 V, 50 Hz RG 7.5
Stand installation The exhibitor’s responsibility. It must follow Portugal’s low-voltage safety regulation, with residual-current main switches and a protective earth, and be done by an electrician accredited by the DGE or the electricians’ union RG 7.2
Connection to the grid Only by FIL’s services, which inspect all electrical work. The exhibitor names the person responsible for the stand’s electrical layout RG 7.6
Ordering Water, drainage, power and telecoms go on the registration form, with the power to be installed. Special lines not on the form: request from FIL 20 calendar days before build-up; they are quoted separately RG 7.8
Stand cleaning The exhibitor’s responsibility; may start no earlier than one hour before the show opens RG 7.10
VAT 23% fil.pt: regulation page, questions tab

Source for the RG rows: FIL General Regulation.

Contractors, build-up and dismantling

  • Contractor accreditation: companies doing build-up and decoration must be accredited in advance, with a civil and professional liability policy of €1,000,000 covering damage to the venue, third parties and stoppage of FIL activities (RG 6.2).
  • Starting work: build-up begins only with the build-up credential and build-up passes (RG 6.1). Passes for build-up staff are ordered on the registration form and must be worn visibly (RG 9.1).
  • Hours: build-up and dismantling hours are set by FIL for each event. Work outside them needs FIL’s express authorisation and an extension fee; both hours and fee appear in the Exhibitor Dossier (RG 6.6).
  • Completion: stands must be finished by the time FIL indicates, or the stand does not open (RG 6.5).
  • Aisles: no loading or unloading in aisles in line with the outdoor gates, so forklifts and lifts can circulate, unless it is the only way to reach the stand (RG 6.8).
  • Dismantling: not before the official closing time (RG 7.11), and finished within FIL’s deadlines. After that, FIL may remove the materials and charge the costs (RG 7.12). The space is handed back in the condition received (RG 7.14).
  • Loading dock access: through the north end of FIL, with authorisation (fil.pt: regulation page, questions tab).

Money and timing

Item Rule Article
Space payment 50% with the participation request; the other 50% by the date in the participation rules RG 4.3
Shell stand and services 50% up front; the rest before build-up starts RG 4.4
Cancellation Up to 60 calendar days before build-up: the initial payments are charged. After that: the full participation cost RG 4.7
Invoice queries Within five working days of receipt RG 4.6
Exhibitor passes Up to 3 modules of 9 m²: 6 passes; one more pass for each additional module RG 9.1
Insurance FIL provides general security; exhibitors guard their own goods and take out specific insurance covering theft RG 10.1

Source: FIL General Regulation.

Getting there and parking

Item Official figure Source
Underground car park 830 spaces, north entrance (by Sony Square) and south entrance (Rua do Bojador), lift or stairs to all four pavilions FIL: Entrances
Parking around the venue More than 10,000 spaces FIL: Entrances
Airport Humberto Delgado Airport, 4 km (approx. 7 minutes) FIL: Location
Public transport Oriente station: train, city bus, express bus, Metro Red Line and taxi FIL: Location
By road A5 motorway and Vasco da Gama Bridge FIL: Location

What this sheet leaves out

FIL publishes no venue-wide figures for the following, so we have not estimated them:

  • an absolute maximum stand height;
  • fire classes for stand materials other than carpet;
  • load limits per rigging point;
  • standard build-up and dismantling hours;
  • door or gate sizes;
  • column positions;
  • power and service prices.

Check your event’s participation rules and Exhibitor Dossier, or ask FIL’s technical area, for these items.

Related FIL Lisbon pages on our site

Fair guides: Sagalexpo, Expodentária.

Need a stand that passes FIL’s technical review first time?

Adam Expo Stand is based in Madrid, Spain, serving all of Europe with a focus on Spain and Portugal. The company was founded in 2018, Adam Dragos has worked in exhibitions since 2005, and we have delivered 639+ projects in 12+ countries. We design, build and install stands. Because FIL bars on-site workshop construction, our fabrication is completed before the stand reaches Lisbon, so it only has to be assembled in the pavilion. As a rough guide, modular stands cost approx. €280–380/m², custom wood approx. €450–650/m² and double-deck approx. €750–1,100/m². Your quote depends on the brief.

Send us your event, pavilion and stand size and we reply within 24 hours. Contact us for your Lisbon stand or see our Lisbon and Portugal stand builder page.